The Dynon is wired through an on/off switch to the main buss, and also to
the essential buss. When the Dynon is turned off and both masters are then
turned off, the Dynon turns itself on and causes the low voltage light on
the essential buss to turn on for just a moment, together with the avionics
fans which run for just a moment. The Dynon then turns itself off after
about 26 seconds and promptly recycles on with the same momentary light and
fans turn on. This continues until the fuse is removed from the keep-alive
wire.
Anybody have any guidance for me? Thanks in advance
Wendell Durr
|
|