Mailing List lml@lancaironline.net Message #66804
From: Mike's Gmail <legacyl2k@gmail.com>
Sender: <marv@lancaironline.net>
Subject: Re: [LML] Legacy hydraulic system
Date: Fri, 06 Sep 2013 07:54:24 -0400
To: <lml@lancaironline.net>
Put on jacks.

Fill system reservoir.

Open dump valve.

Turn on pump.  Refill reservoir as required.

Once fluid stabilizes move gear handle to up position.  Once fluid stabilizes again close dump valve.

Cycle gear.

Top off fluid.

Done!

 

Sent from my iPhone

On Sep 5, 2013, at 9:10 PM, Berni Breen <bbreen@cableone.net> wrote:

My IO550 Lancair Legacy has been down for about 6 months.  Before flying I need to fill and test the gear on the ground.  The lines were disconnected and I need to insure that the system is full of fluid and there is zero air in the system.  Can someone give me a procedure to refill my system properly before I test the gear?  What fluid is recommended?

Sent from my iPad
Berni Breen
Bbreen@cableone.net
--