Rick,
Perhaps you had over voltage conditions (16+ VDC). If you were using
a B&C LR3C regulator, the OV Crowbar logic would pop the field
breaker.
If you are using something else.................
Scott Krueger
In a message dated 10/6/2009 12:24:00 P.M. Central Daylight Time,
rickargente@gmail.com writes:
Hello all,
I flew my 360 to Tangier Island yesterday and
on the way back to Princeton, NJ, my ALT FLD CB popped out at least four
times during the short 45 minute trip. In the past, occasionally,
this CB will pop out write after I start the engine and that would be
it. Anybody on the list have had a similar problem with the Alt Field
popping out? Please advise.
Thanks much, Rick
Argente N360ZR (believe it or not, with over 1,000 hours
now!)
-- For archives and unsub