Your probes output 10kHz signal, that needs to be converted to 0-5v for your inputs. Todd sells the units to do that. I just upgraded my two units in the Legacy from 5-point devices to 11-point so if you want two of the 5-points I can make a deal on those with you. The 5-point means you have 5 calibration points in the fuel tank and then the unit interpolates between those five points (Empty, Full and 3 others).
Paul
Does anyone have experience with hooking VM1000 fuel probes to Dynon Skyview system? After all tried and done, it appears that the probe’s output is in frequencies and the Dynon accepts up to 5 volts as input. JPI tech told us they used to make an adapter, but they don’t anymore. Does anyone know of such or similar adapter?
Henry Arjad, KSNA
LEG2 N22YY 40 hours
Henry@cptgroup.com
949.500.6847