Had similar issues with just the backup alternator system.  I put a recording voltmeter on the circuit to try to diagnose.  Found voltage spikes that tripped the regulator.  Changed alternators, batteries, a lot of wiring and B&C regulators before I found the very slightly loose ground connection on the firewall. Hasn't been a problem since.  Would recommend a thorough check of all ground connections on engine, alternators, batteries and into airframe before replacing other "parts."  I am convinced that your problem is with a ground as that's probably the only common connection between the two charging systems.

Barry Knotts
L-IV P, N4XE

On 3/5/2012 8:21 AM, Craig Gainza wrote:
Dear Listers,

Recently, I completed my annual and test flew the airplane.  Upon lifting the gear both primary and secondary alternator field breakers popped.  Pushed them back in and all charging returned to normal on the primary and secondary alternators. 

Landed, checked connections, put in a different battery, ran through B and C voltage regulator troubleshooting guide (came out normal)  and did a ground run up.  When lifting the flaps, hydraulic pump kicked on both field breakers popped again.  Right now I am assuming it is the voltage regulator (both pri and sec are B and C), alternator , or a connector.

Anyone have similar issues and can recommend the next course of action?

Thank you,

Craig Gainza
IV-P TSIOF 550
 782 hours and holding