| I had one in my 235/320 and the optical sensors didn't work, nor did the control unit... and they had no substitute or repairs available. I finally took it out in put toggle switched in for each Facet transfer pump to the header, and in the header put in a float switch that woujld interrupt the Facets when the fuel level in the header was to the shutoff level desired. Works fine. Terrence L235/320 N211AL On Jan 22, 2010, at 9:35 AM, Novelli wrote: Sílvio Novelli Lancair 320 - PP-XSN +55 (14) 3841-2337 From: Lancair Mailing List [mailto:lml@lancaironline.net] On Behalf Of Tom Anderson Sent: quinta-feira, 21 de janeiro de 2010 19:53 To: lml@lancaironline.net Subject: [LML] Automatic header tank feeder My 360 is getting ready for some repairs that includes fixing defective fuel gauges and recalibrating my totalizer. While I’m at it, I’d like to add a switching device that would read the header tank level and automatically activate the fuel transfer pumps when the header tank level drops below, say, 4 gallons and then shuts it off at a header tank reading of about 9 gallons. I saw a 2 ¼” display for such a unit on a friend’s Lancair, but he couldn’t recall where he got if from and doubted they were still available. Does anyone know if they are or what other options might be available? Thanks for any thoughts on this. Tom, N360DB
|
|