What he said! Very common question that I get and this is the correct
answer. DO NOT try to directly match the load with the breaker (or fuse if
you insist) rating.
Tracy
----- Original Message -----
Sent: Wednesday, January 19, 2005 9:00
PM
Subject: [FlyRotary] Re: Fuel Pump
Load
I would be very inclined to use a dedicated breaker for each
pump and
make them about double what the pump draw is. You're not
protecting the
pump IMO, but the wire leading to the pump (so a dead short
doesn't set
fire to your airplane). The LAST thing I'd want is a
spurious / false
break (particularly if it shuts down ALL my pumps.
I'd
go for 15A or so ... Jim S.
jewen wrote:
>Can anyone let me
know what the full load current is for
>fuel pumps being used on Rotary
applications. I am sizing
>the wiring and
braeker.
>Thanks,
>Joe
>
>
>