Mailing List lml@lancaironline.net Message #68479
From: Steve Colwell <mcmess1919@yahoo.com>
Sender: <marv@lancaironline.net>
Subject: Bendix S4LN-21 Mag shorted?
Date: Tue, 10 Dec 2013 08:40:45 -0500
To: <lml@lancaironline.net>

 

John,

 

When the connector to the P-lead wire at one mag was installed and the P-lead Shield was stripped, the cut went through the P-lead insulation.  It didn’t show up for about 300 hours until it started intermittently shorting for about 1 minute then it would be OK for hours.  Mucho time checking/testing went into that one.  The wire had to be moved just right to short.   

 

Steve Colwell  Legacy 550

 

But this saga isn't over yet, because I checked the right mag and it reads open at the P-lead terminal. To be continued...