| Valin: Ditch that piece. Get the flush mounted valve on the other outlet. Safety wire the valve, leave the cap on with the o-ring. When time for oil change, unscrew the cap, screw on the adapter with the hose, drain into bucket, take oil sample, drill the top of filter with a 1/8 inch hole and leave it overnight. The next morning oil is gone, swap filter with no drops spilled, replace the cap on the drain and fill-r-up. Painless.
|
|