Return-Path: Received: from spdmgaab.compuserve.com ([149.174.206.135]) by ns1.olsusa.com (Post.Office MTA v3.5.3 release 223 ID# 0-64832U3500L350S0V35) with ESMTP id com for ; Wed, 2 Aug 2000 10:14:46 -0400 Received: (from mailgate@localhost) by spdmgaab.compuserve.com (8.9.3/8.9.3/SUN-1.9) id KAA14441 for lancair.list@olsusa.com; Wed, 2 Aug 2000 10:21:11 -0400 (EDT) Date: Wed, 2 Aug 2000 10:20:03 -0400 From: James Frantz Subject: Enough with Diodes Sender: James Frantz To: "INTERNET:lancair.list@olsusa.com" Message-ID: <200008021021_MC2-AE4B-B734@compuserve.com> X-Mailing-List: lancair.list@olsusa.com Reply-To: lancair.list@olsusa.com Mime-Version: 1.0 <<<<<<<<<<<<<<<<--->>>>>>>>>>>>>>>> << Lancair Builders' Mail List >> <<<<<<<<<<<<<<<<--->>>>>>>>>>>>>>>> >> >1. An overvoltage transient from a failed alternator will arrive at the anode of the diode(s), i.e., in the "forward direction", and will not stress the reverse capability, regardless of it's voltage rating.< The overvoltage will produce an over current. The current rating of the proposed isolation diode was too small. The max forward voltage rating of the diode was too small and the max peak reverse voltage rating may be too small as well depending upon what is on the isolation bus! By the time you properly size the diode, you may be back with the large voltage drop across the diode which was earlier found to be unacceptable. >2. As long as either battery is connected to the bus, most of any "failure transient" will be absorbed by the battery. If you had one of Bob Nuckoll's overvoltage crow-bar circuits (or equivalent) installed, the alternator breaker should trip off when the voltage rose to maybe 18 - 20 volts anyway and the surge wouldn't be excessive.< "As long as" and "if" is a big statement. Ever hear of poor battery connections and poor grounds or a master relay failure? Was the proposed diode tested in this failure mode? Did the system include overvoltage protection? You could be up there IFR with no instruments, no gyros, and no engine assuming you opted to go with an all electric gyro system and an all electric ignition system. You may want to talk with George Stevenson (651) 454-3745 who had an overvoltage which blew up his battery (the sink) and fried his diode (the isolation). The result was that his backup battery was powering everything but was only intended to power the electronic ignition system. Fortunately, George did an emergency gear extendsion else the engine may have quit as he attempted to electrically put the gear down. This incident was reported in the LNN several years ago and is a good lesson in failure mode analysis. Because of the fried diode his little ignition battery actually powered down the flaps. Lucky this didn't cause to battery voltage to pull low and his engine electronic system to quit. >3. Regardless, even without that device, your diode wouldn't see a reverse voltage - alternators just don't fail where their output voltage goes negative.< I never stated that alternators fail with a reverse voltage. Lots of other devices do cause large reverse voltages such as inductive loads when they are switched off. And we have lots of inductive devices in our aircraft. I can list 22 in mine including one really big one the hydraulic pump. My advise is to forget diode isolation systems unless you are confidant that you understand all the issues that are important in designing a isolation system and test it. From what I saw on an earlier post, the issue is not that well understood, the common failure modes had not been considered nor could the system have been easily tested for those failure modes that would be expected. I submitted the previous comments based upon an earlier Lancair pilot's actual experience with an isolation diode system. The over voltage and subsequent events could have resulted in a deadly incident! In this case, the incident cost only $$$ about 3,000 of them. See issue 22 page 271 of the Lancair Network News. BTW, overvoltage protection is a must! At least we argree on one point. Jim Frantz >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> LML website: http://www.olsusa.com/Users/Mkaye/maillist.html LML Builders' Bookstore: http://www.buildersbooks.com/lancair Please send your photos and drawings to marvkaye@olsusa.com. >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>