X-Virus-Scanned: clean according to Sophos on Logan.com Return-Path: Sender: To: lml@lancaironline.net Date: Fri, 30 Mar 2012 22:55:28 -0400 Message-ID: X-Original-Return-Path: Received: from bay0-omc3-s3.bay0.hotmail.com ([65.54.190.141] verified) by logan.com (CommuniGate Pro SMTP 5.4.4) with ESMTP id 5461997 for lml@lancaironline.net; Fri, 30 Mar 2012 00:13:25 -0400 Received-SPF: pass receiver=logan.com; client-ip=65.54.190.141; envelope-from=jraddison@msn.com Received: from BAY158-W60 ([65.54.190.189]) by bay0-omc3-s3.bay0.hotmail.com with Microsoft SMTPSVC(6.0.3790.4675); Thu, 29 Mar 2012 21:12:50 -0700 X-Original-Message-ID: X-Original-Return-Path: jraddison@msn.com Content-Type: multipart/alternative; boundary="_a6add83b-1ad1-492f-95dd-1771ecbf1c5e_" X-Originating-IP: [75.196.56.7] From: JON ADDISON X-Original-To: Lancair Mailing List Subject: Hydraulic leaks X-Original-Date: Thu, 29 Mar 2012 21:12:50 -0700 Importance: Normal MIME-Version: 1.0 X-OriginalArrivalTime: 30 Mar 2012 04:12:50.0160 (UTC) FILETIME=[5EDDF700:01CD0E2B] --_a6add83b-1ad1-492f-95dd-1771ecbf1c5e_ Content-Type: text/plain; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable Danny=2C I'm not the expert like some out there=2C but I will say to you th= at since I overhauled every hyd actuator with Lancair supplied "kits" all l= eaks and weeps have stopped. Additionally=2C the origional hoses were all= deteriorating and one actually weeped right out of the middle of one hose = in the nose wheel well (it looked like it came out of a joint=2C but no.). = Replaced all 14 with teflon/ss outer hosed from Flowline (custom made and= very economical). For good measure added up and down gages as I posted r= ecently. As Chris Z said=2C gages in the cockpit explain a lot in real time. They = take a lot of wondering out of the equation. Jack AddisonMark II 360=2C high comp = --_a6add83b-1ad1-492f-95dd-1771ecbf1c5e_ Content-Type: text/html; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable
Danny=2C I'm not the expert like some out there=2C but I will say to you th= at since I overhauled every hyd actuator with Lancair supplied "kits" all l= eaks and weeps have stopped.  =3B Additionally=2C the origional hoses w= ere all deteriorating and one actually weeped right out of the middle of on= e hose in the nose wheel well (it looked like it came out of a joint=2C but= no.).  =3B Replaced all 14 with teflon/ss outer hosed from Flowline (c= ustom made and very economical).  =3B For good measure added up and dow= n gages as I posted recently.

As Chris Z said=2C gages i= n the cockpit explain a lot in real time.  =3B They take a lot of wonde= ring out of the equation.

Jack Addison
M= ark II 360=2C high comp
= --_a6add83b-1ad1-492f-95dd-1771ecbf1c5e_--