Hi Valin,
 
I looked at this seriously but at the time there was very limited information available on the web site for evaluating the failure mode.
My biggest concern about a starter contactor is that there is the potential for a dead short in the starter and I want to know I can get the thing turned off.  If you look at the dead short current on an Odyssey battery, it's impressive.  With a mechanical relay, you are counting on the spring to open the contacts.   With a solid state device you are hoping that it doesn't fail in a way that conducts current.   I don't know what this one does and couldn't figure it out so I passed.  Maybe one of the EE's on the list could provide some insight and know how to ask the question of the vendor.  (e.g. what heppens to your device when I give it 1500 amps for 1 sec?)
 