Craig,
As a first start, check your ground wires…all of them, and especially the
grounds to the B&C regulator and the regulator case. These regulators have
an overvoltage protection circuit that works by tripping the field breaker. This
circuit is easily triggered by spurious noise in the electrical system caused
by bad grounds. Loose primary wiring will also cause this, but not as easily. Don’t
be tempted to just install a larger breaker as one Lancair owner did!
I have the same setup you do,
and have had no problems at 450 flight hours to date. If I can help you
troubleshoot, contact me off-line.
Bob
757-286-4802 cell
Craig
Berland wrote:
My IV-P has a charging problem. The alternator 5 amp
field circuit breaker pops. It seems to take longer to pop when there is
a higher electrical load. For example when the air conditioner is
running. I have a 24v system, 100 amp alternator, B&C voltage
regulator and two 12 v gel cell batteries in series. Any thoughts
as to where I should look?