Bill,
I recently had the same problem
as yourself but with a slight difference. My pump would run continuously with
gear down selected ( on jacks as I'm not flying yet), but was fine with gear up.
I have pressure gauges and was able to see that the pressure switch was not
opening and the pump had reached it's internal pressure relief point and was
bypassing. Resetting the breaker made no difference but a light tap on the
pressure switch unstuck the switch and the pump stopped. You might try that to
see if it isolates the problem. I have already received the new low pressure
switchfrom Lancair and am awaiting the back ordered high pressure switch. The
new ones look much more substantial and as I understand it the point at which
the switch closes is adjustable via a screw at the top of the switch. $71
plus S&H each solved the problem.
Kai Ogston
|
|