Bryan,
   Try adjusting the sequence valve so it contacts the gear leg a bit more, or as a temporary fix, wrap the gear leg contact point where it hits the sequence valve with a couple wraps of tape. That may easily eliminate one area of concern..    Don Skeele A&P
----- Original Message -----
Sent: Sunday, May 24, 2009 12:11 AM
Subject: [LML] Hydraulic issues?

When I cycle my gear all my gear goes up but the gear doors only close half way then a second or 2 later the motor burps and the gear doors close a little more..then a second later burp and and they shut completly. 

Why is it doing this? Do I need to adjust the high pressure switch? Is there a leak in the system?

thanks
Bryan