X-Virus-Scanned: clean according to Sophos on Logan.com Return-Path: Sender: To: lml@lancaironline.net Date: Mon, 24 Mar 2008 07:44:38 -0400 Message-ID: X-Original-Return-Path: Received: from colossus.formysite.com ([64.58.34.10] verified) by logan.com (CommuniGate Pro SMTP 5.2.1) with ESMTPS id 2814548 for lml@lancaironline.net; Sun, 23 Mar 2008 13:42:06 -0400 Received-SPF: none receiver=logan.com; client-ip=64.58.34.10; envelope-from=genemartin@enid.com Received: from gene ([66.138.13.85]) by colossus.formysite.com (8.12.8/8.12.8) with SMTP id m2NHfMMb028118 for ; Sun, 23 Mar 2008 12:41:26 -0500 X-Original-Message-ID: <009301c88d0d$41ec36f0$0a01a8c0@gene> From: "genemartin" X-Original-To: "Lancair Mailing List" References: Subject: Re: [LML] Location for Strobe Power Supply in 320? X-Original-Date: Sun, 23 Mar 2008 12:41:47 -0500 MIME-Version: 1.0 Content-Type: multipart/alternative; boundary="----=_NextPart_000_0079_01C88CE3.42049300" X-Priority: 3 X-MSMail-Priority: Normal X-Mailer: Microsoft Outlook Express 6.00.2900.3138 X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2900.3198 This is a multi-part message in MIME format. ------=_NextPart_000_0079_01C88CE3.42049300 Content-Type: text/plain; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable mine is on the aft. side of the firewall Gene Martin LNC2/320 ----- Original Message -----=20 From: Christopher Skelt=20 To: lml@lancaironline.net=20 Sent: Saturday, March 22, 2008 8:40 PM Subject: [LML] Location for Strobe Power Supply in 320? Folks, Can anyone recommend a location for a Whelen HDA-CF 14/28 power supply = in a 320? My original plan was to mount it behind the seat, but I'm = reluctant to have the high voltage lines share the central console with = the NAV, COM and XPDR coaxes as they would run parallel, only a few = inches away. Any alternative run along the floor or outer skins would = likely be messy. One possibility is on the front side of the mainspar, = inboard of the wing spar extension, but that would encroach on the = already cosy cockpit, though hopefully not too much. I would appreciate = any suggestions, positive and negative experiences, warnings and photos. Thanks in advance, Chris Skelt. cskelt@earthlink.net ------=_NextPart_000_0079_01C88CE3.42049300 Content-Type: text/html; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable
mine is on the aft. side of the = firewall
Gene Martin
LNC2/320
----- Original Message -----
From:=20 Christopher=20 Skelt
Sent: Saturday, March 22, 2008 = 8:40=20 PM
Subject: [LML] Location for = Strobe Power=20 Supply in 320?

Folks,
Can anyone recommend a location for a Whelen HDA-CF 14/28 power = supply in=20 a 320? My original plan was to mount it behind the seat, but I'm = reluctant to=20 have the high voltage lines share the central console with the NAV, = COM and=20 XPDR coaxes as they would run parallel, only a few inches away. Any=20 alternative run along the floor or outer skins would likely be messy. = One=20 possibility is on the front side of the mainspar, inboard of the wing = spar=20 extension, but that would encroach on the already cosy cockpit, = though=20 hopefully not too much.  I would appreciate any=20 suggestions, positive and negative experiences, warnings and = photos.
 
Thanks in advance,
Chris Skelt.
 
 
 
 

------=_NextPart_000_0079_01C88CE3.42049300--