Mailing List lml@lancaironline.net Message #45201
From: <TByrnes133@aol.com>
Sender: <marv@lancaironline.net>
Subject: Re: [LML] emailable diagram of IVP hydraulic system
Date: Tue, 04 Dec 2007 07:23:38 -0500
To: <lml@lancaironline.net>
Colyn
 
There is a solenide with a pin that retracts when airspeed exceeds 70 Knts.  The pin goes into a detent in the gear switch barrel.  If that solenide is defective or is not getting power, the leaver cannot be moved out of the down position.  This solenide is activated by an airspeed switch.
 
Tom Byrnes Lancair IV N54TB