X-Virus-Scanned: clean according to Sophos on Logan.com Return-Path: Received: from [67.8.181.30] (account marv@lancaironline.net) by logan.com (CommuniGate Pro WEBUSER 5.1.9) with HTTP id 2079458 for lml@lancaironline.net; Fri, 01 Jun 2007 19:54:54 -0400 From: marv@lancair.net Subject: Re: [LML] TSIO 550 LOP To: X-Mailer: CommuniGate Pro WebUser v5.1.9 Date: Fri, 01 Jun 2007 19:54:54 -0400 Message-ID: In-Reply-To: <36D4307D-E26A-467F-B95B-0D21A89D710B@advancedpilot.com> References: <36D4307D-E26A-467F-B95B-0D21A89D710B@advancedpilot.com> MIME-Version: 1.0 Content-Type: text/html;charset=windows-1252 Content-Transfer-Encoding: 8bit
Posted for Walter Atkinson <walter@advancedpilot.com>:

The latency period is that time between the spark event and the initiation
of the flame front. IOW, how long it takes the fuel to begin to burn. This
helps the designer select the correct timing and is instrumental in
detonation resistance of a fuel.

Walter


Bill Hannahan wrote:
"""
Walter,
Please define “latency period”.
"""