Mailing List lml@lancaironline.net Message #39838
From: Kevin Kossi <kevin@airforcemechanical.com>
Sender: <marv@lancaironline.net>
Subject: Re: [LML] Re: DH Lines
Date: Sun, 04 Feb 2007 20:12:42 -0500
To: <lml>
Great,

I will forward this list to Tim, at Lancair. He said he needed five to put a package together.
I have to clarify with Tim, if that was a total of five in all models or five in each model.
Either way we have five for the IV.
Since we have a total of nine sets, hopefully Tim can get a wholesale price from DH and get us a better price.


So for the lV we have:  

1. Pat Cohenour                    IV-P

2. Bill George                       IV-P

3. Craig B.                           IV-P

4. Bill Harrelson                   IV
5. Bill Edwards                     IVP

So far for the Legacy we have:

1. Kevin Kossi          Legacy
2. Dan Ballin            Legacy

3. Ken Rice              Legacy

4. Bob Mackey         235



Kevin Kossi

Image
flextubes.gif
A three-ply, polyamide-fabricbraid-polyamide, flexible tube with factory installed 400 or 300 Series stainless 
steel tips.

Used in systems where high pressure flexible connections are needed to facilitate frequent make and break operations, 
allow individual movement of components under pressure and/or withstand high frequency vibration.
Weather Inert to ozone and ultraviolet. Safety Burst pressure of 20 000 psi for a 3:1 margin with operating pressure.
Aging Negligible humidity absorption. Growth Less than 5% physical change overall at maximum operating pressure.
Flexibility Bending radius of 15/16 in. at maximum operating pressure. Chemical Resistance Compatible with an
extremely wide range of liquid and gas media.


Lightweight - Tube weight is only 0.5 oz/yd of length (16 g/m).

Working Pressure - Up to 6 000 psi (41 MPa).

Flexibility - Bending radius of 15/16 in. (2.4 cm) at maximum operating pressure.

Temperature - No derating of operating pressure for temperatures from -30 to 100 °F (-34 to 38 °C).

Weather - Inert to ozone and ultraviolet

Safety - Burst pressure of 20 000 psi (138 MPa) for a 3.3 margin with operating pressure.

Aging - Negligible humidity absorption

Growth - Less than 5% physical change overall at maximum operating pressure

Chemical Resistance - Compatible with an extremely wide range of liquid and gas media



Posted for Kevin Kossi <kevin@airforcemechanical.com>:

I spoke to Tim at Lancair, he said that they do not currently sell  the DH
lines and that they are are very nice to use and compact.
They are expensive…on the order of $500-$600 probably for a set of  lines for
the legacy.

If at lease five people are interested in ordering a set, he will do  the
engineering and put a package together for the Legacy.
I'm in for one.


Kevin Kossi
Legacy 73%
New York




Subscribe (FEED) Subscribe (DIGEST) Subscribe (INDEX) Unsubscribe Mail to Listmaster