Return-Path: Received: from smtp2.gateway.net ([208.230.117.246]) by truman.olsusa.com (Post.Office MTA v3.5.1 release 219 ID# 0-52269U2500L250S0V35) with ESMTP id com for ; Sat, 20 Nov 1999 01:51:22 -0500 Received: from oemcomputer (1Cust118.tnt2.coeur-dalene.id.da.uu.net [63.20.49.118]) by smtp2.gateway.net (8.9.3/8.9.3) with SMTP id BAA04629 for ; Sat, 20 Nov 1999 01:55:48 -0500 (EST) Message-ID: <000701bf3324$9d65d8c0$7631143f@oemcomputer> Reply-To: "dfs" From: "dfs" To: "Lancair List" Subject: Solenoid Date: Fri, 19 Nov 1999 22:57:28 -0800 X-Mailing-List: lancair.list@olsusa.com Mime-Version: 1.0 <<<<<<<<<<<<<<<<--->>>>>>>>>>>>>>>> << Lancair Builders' Mail List >> <<<<<<<<<<<<<<<<--->>>>>>>>>>>>>>>> >> To Bill Hogarty, re: a solenoid that will last for an hour whilw energized. Bill, you've got one (or da-- well should have one) in your airplane right now - it's called the "master relay" or some such. Cheap as a Big Mac and far more reliable. Just be sure to use the one intended for the master relay position. It's on all the time your master switch is on and is quite capable of carrying a lot of current - might I point out that the garden variety "master relay" happily carries the starter current (which can be a couple hundred amperes) without too much problem. Just be sure that you don't choose a "stater relay" which has a very low coil resistance and shouldn't have power applied for more than a few seconds at a time. Another possible choice is the automotive high current relays. They look like a small black cube (maybe 1 to 11/4 inches on a side) and are available in ratings up to 70 amps at 12 volts DC. The relay manufacturers, Bosch and Guardian and a couple others, make them and they are quite reliable. I've used them in my airplane for over 500 hours and have yet to have a failure. Granted, I'm not using them for starting motor loads but they are double-break type relays and should fill the bill. Dan Schaefer [Dan... I think what Bill is looking for is a solenoid only, forget the contacts part of the relay. Seems to me he wants to use the movable solenoid part of the relay as a mechanical actuator for his flap door. Then again, maybe I misunderstood his original post as well . I imagine one could take a master relay and cabbage the contacts end of it and turn it into a pretty compact linear actuator. I think the stroke would be way too short, though, given the operating characteristics of a typical power relay. If I'm way off base here, never mind . ] >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> LML website: http://www.olsusa.com/Users/Mkaye/maillist.html Builders' Bookstore: http://www.buildersbooks.com/lancair >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>