X-Virus-Scanned: clean according to Sophos on Logan.com X-SpamCatcher-Score: 30 [X] Return-Path: Sender: To: lml Date: Sat, 02 Dec 2006 22:51:20 -0500 Message-ID: X-Original-Return-Path: Received: from mail25.syd.optusnet.com.au ([211.29.133.166] verified) by logan.com (CommuniGate Pro SMTP 5.1.3) with ESMTPS id 1633301 for lml@lancaironline.net; Sat, 02 Dec 2006 19:40:18 -0500 Received-SPF: none receiver=logan.com; client-ip=211.29.133.166; envelope-from=fredmoreno@optusnet.com.au Received: from fred (optussatellitebintb.22bjipb002.optus.net.au [59.154.24.148] (may be forged)) (authenticated sender fredmoreno) by mail25.syd.optusnet.com.au (8.13.1/8.13.1) with ESMTP id kB30dfno007645 for ; Sun, 3 Dec 2006 11:39:50 +1100 From: "Fred Moreno" X-Original-To: "Lancair Mail" Subject: FW: [LML] Re: New (2006) TSIO550E Lean of Peak (LOP) Operation X-Original-Date: Sun, 3 Dec 2006 09:39:28 +0800 X-Original-Message-ID: <006501c7167b$e625e4a0$c211140a@fred> MIME-Version: 1.0 Content-Type: text/plain; charset="windows-1250" Content-Transfer-Encoding: quoted-printable X-Priority: 3 (Normal) X-MSMail-Priority: Normal X-Mailer: Microsoft Outlook, Build 10.0.6626 X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2900.2962 Importance: Normal Posted for Walter Atkinson : The HP multiplier for LOP is based on the BSFC(min). In the engines = with 8.5:1 CR it is 14.9. In the 7.5:1 engines it is about 13.7. =20 Walter ________________________________________________________ =20 Assuming avgas is 6 pounds per gallon, then one can compute the brake specific fuel consumption as follows:=20 7.5 compression, 6/13.7 =3D 0.438 pounds/hp hour 8.5 compression, 6/14.9 =3D 0.403 pounds/hp hr From this we might extrapolate for those IO-550N's engines with 10 compression (recognizing the benefits of compression increases diminish = as compression increases) that=20 10 compression =3D 0.37 lbs/hp hr (implying that you would use a figure = of 16.1 All of this is conditioned on lean of peak operation, all the fuel being burned. If you go into the Columbia 350 operating manual (available on line) and work through the power tables, for 50F LOP operation below 65%, the = implied SFC is 0.38-0.39 instead of 0.40 (above). That is probably wishful = thinking given the nature of Continental stock fuel injectors. =20 What think you, Walter? Fred Moreno --=20 No virus found in this outgoing message. Checked by AVG Free Edition. Version: 7.1.409 / Virus Database: 268.15.5/564 - Release Date: = 2/12/2006 =20