X-Virus-Scanned: clean according to Sophos on Logan.com Return-Path: Sender: To: lml Date: Tue, 01 Aug 2006 14:29:56 -0400 Message-ID: X-Original-Return-Path: Received: from elasmtp-scoter.atl.sa.earthlink.net ([209.86.89.67] verified) by logan.com (CommuniGate Pro SMTP 5.1c.2) with ESMTP id 1331691 for lml@lancaironline.net; Tue, 01 Aug 2006 10:13:58 -0400 Received-SPF: none receiver=logan.com; client-ip=209.86.89.67; envelope-from=leighton@teleport.com DomainKey-Signature: a=rsa-sha1; q=dns; c=nofws; s=dk20050327; d=teleport.com; b=kP6epLufAutRwbY4MW034Cu81cIDDtFyguPuZgVOoMqf0jLa4boUUlLVYqCHPt90; h=Received:Message-ID:From:To:Subject:Date:MIME-Version:Content-Type:X-Priority:X-MSMail-Priority:X-Mailer:X-MimeOLE:X-ELNK-Trace:X-Originating-IP; Received: from [4.242.171.42] (helo=user) by elasmtp-scoter.atl.sa.earthlink.net with asmtp (Exim 4.34) id 1G7uze-0004HR-Pb for lml@lancaironline.net; Tue, 01 Aug 2006 10:13:11 -0400 X-Original-Message-ID: <005901c6b574$9ffe3a30$2aabf204@user> From: "Leighton" X-Original-To: "Lancair Mail list" Subject: LR3C Regulator X-Original-Date: Tue, 1 Aug 2006 07:13:10 -0700 MIME-Version: 1.0 Content-Type: multipart/alternative; boundary="----=_NextPart_000_0056_01C6B539.F24A8090" X-Priority: 3 X-MSMail-Priority: Normal X-Mailer: Microsoft Outlook Express 6.00.2900.2869 X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2900.2869 X-ELNK-Trace: ea0fe3d44b30ba0fc355332e9c4b49d598c48853aa0a5d8988fc5ea0f2509c4b94d9e24b94edfa06350badd9bab72f9c350badd9bab72f9c350badd9bab72f9c X-Originating-IP: 4.242.171.42 This is a multi-part message in MIME format. ------=_NextPart_000_0056_01C6B539.F24A8090 Content-Type: text/plain; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable The B&C regulator works well on either side of the firewall but I have = found that it is important to mount them in such a manner that the = voltage adjusting screw is easily accessible. It's a small slotted = screw located under a black rubber plug. We discovered that the = regulators come set at about 14.2 volts and if the Concorde RG batteries = are charged at that rate they do not last long. Adjusting the voltage = down to the recommended 13.8 solves the problem. So plan ahead on where = it's mounted. Leighton Mangels ------=_NextPart_000_0056_01C6B539.F24A8090 Content-Type: text/html; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable
The B&C regulator works well on either side of = the=20 firewall but I have found that it is important to mount them in such a = manner=20 that the voltage adjusting screw is easily accessible.  It's a = small=20 slotted screw located under a black rubber plug.  We discovered = that the=20 regulators come set at about 14.2 volts and if the Concorde RG batteries = are=20 charged at that rate they do not last long.  Adjusting the voltage = down to=20 the recommended 13.8 solves the problem.  So plan ahead on where = it's=20 mounted.
 
Leighton Mangels
------=_NextPart_000_0056_01C6B539.F24A8090--