Mailing List lml@lancaironline.net Message #11121
From: Marvin Kaye <74740.231@compuserve.com>
Sender: Marvin Kaye <74740.231@compuserve.com>
Subject: Re: LNC2 Gear extension problem - false indication
Date: Wed, 26 Sep 2001 14:35:44 -0400
To: Lancair Mail List <lancair.list@olsusa.com>
         <<<<<<<<<<<<<<<<--->>>>>>>>>>>>>>>>
         <<  Lancair Builders' Mail List  >>
         <<<<<<<<<<<<<<<<--->>>>>>>>>>>>>>>>

Posted for "Ed de Chazal" <edechazal@mindspring.com>:

Related to Matt's gear problem on his LNC2, I recently had a problem with the left main gear extending.  The indicator light would not come on while the other 2 were illuminated as usual.  The emergency extension seemed to work.  While taxiing the gear light went out.  On jacks, I removed the terminals from the microswitch, re-attached them, and the light came on and stayed on.  Seems to be a little corrosion at the terminal interfaces.  There were no other problems noted with the linkages or hydraulic functioning.  These microswitches are all exposed and not waterproof and this kind of false indication is not what one needs.  Has anyone else experienced this and have recommendations to prevent?

Regards,
Ed de Chazal

LML website:   http://www.olsusa.com/mkaye/maillist.html
LML Builders' Bookstore:   http://www.buildersbooks.com/lancair

Please send your photos and drawings to marvkaye@olsusa.com.

Subscribe (FEED) Subscribe (DIGEST) Subscribe (INDEX) Unsubscribe Mail to Listmaster