A properly flared AN fitting will not leak. If it does it means that the
flare is damaged or the "B" nut is not tight enough. So, tighten the nut
or remake the flare. Spruce has Teflon donuts the fit over the flare
cone for those seeking a short cut.
Bruce
WWW.Glasair.org -----Original Message-----
From: Lancair Mailing List [mailto:lml@lancaironline.net] On Behalf Of
Rob Murawski
Sent: Tuesday, May 22, 2012 9:32 AM
To: lml@lancaironline.net
Subject: [LML] Sealant for hydraulic lines (LNC2)
I'm starting to install hydraulic cylinders, but still pretty far off
from
permanently connecting or running anything hydraulic.
The manual recommends Recoseal (tm) and I have no idea what that is.
What
sealer are people recommending now for the AN hydraulic fittings?
Anything
I can get from say Aircraft Spruce or the like?
Thanks,
-Rob
Lancair 360 MKII
Pittsburgh, PA
--