X-Virus-Scanned: clean according to Sophos on Logan.com Return-Path: Received: from [66.94.81.250] (account marv@lancaironline.net) by logan.com (CommuniGate Pro WebUser 5.0c1) with HTTP id 670835 for lml@lancaironline.net; Tue, 16 Aug 2005 12:57:02 -0400 From: "Marvin Kaye" Subject: Re: [LML] Lancair 320/360 Gear Relay Failure To: lml X-Mailer: CommuniGate Pro WebUser v5.0c1 Date: Tue, 16 Aug 2005 12:57:02 -0400 Message-ID: In-Reply-To: References: MIME-Version: 1.0 Content-Type: text/plain; charset="ISO-8859-1"; format="flowed" Content-Transfer-Encoding: 8bit Posted for "Christopher Zavatson" : Rick, I haven't had this problem, but I would suggest opening up the old relay to see what exactly failed. Did the coil fail? Did the plunger get stuck? Was the problem actually in the pump motor? I did find a brand new relay of this type with a broken coil wire (manufacturing defect). I still have it on display here in my office. Chris Zavatson > Upon close inspection, I noticed that the 'gear-down' relay was very hot