X-Virus-Scanned: clean according to Sophos on Logan.com Return-Path: Received: from imr-m06.mx.aol.com ([64.12.138.200] verified) by logan.com (CommuniGate Pro SMTP 5.2c4) with ESMTP id 2643780 for flyrotary@lancaironline.net; Sun, 13 Jan 2008 20:19:50 -0500 Received-SPF: pass receiver=logan.com; client-ip=64.12.138.200; envelope-from=BMears9413@aol.com Received: from imo-d04.mx.aol.com (imo-d04.mail.aol.com [172.18.150.228]) by imr-m06.mx.aol.com (v107.10) with ESMTP id RELAYIN10-b478ab88e21a; Sun, 13 Jan 2008 20:19:10 -0500 Received: from BMears9413@aol.com by imo-d04.mx.aol.com (mail_out_v38_r9.3.) id q.c7b.2440e909 (14502) for ; Sun, 13 Jan 2008 19:48:59 -0500 (EST) From: BMears9413@aol.com Message-ID: Date: Sun, 13 Jan 2008 19:48:59 EST Subject: Re: [FlyRotary] Re: EC2 To: flyrotary@lancaironline.net MIME-Version: 1.0 Content-Type: multipart/alternative; boundary="-----------------------------1200271739" X-Mailer: 9.0 Security Edition for Windows sub 5379 X-Spam-Flag: YES X-AOL-IP: 172.18.150.228 -------------------------------1200271739 Content-Type: text/plain; charset="US-ASCII" Content-Transfer-Encoding: 7bit So the solid state does the same thing as the old mechanical relay....makes sense....I thought it might have needed an update to the EC2 for the solid state relay. I do have power to my secondary injectors, i just cant hear them click. Whats the proper test to check out the injectors? I checked them with a test light and have power to one side, then when I check the other side (ground with a test light), I get a click from the connector to my suprise. must be those resistors Bob installed??? Just didn't expect any noise from there. I'll send my EC2 to you Tracy for an update. I'm not criticizing about updates, sorry if you took it that way.....when i said i was downloading the manual instead of working... I should have said....at work. I scour your web page daily looking for any 20B updates...once again at work....when I should be working. I dont have any qualms about paying for an update.....glad your there to do it. I'll remove it tonight and send it tomorrow. Thanks everyone for the info Bob Mears Supermarine Spitfire **************Start the year off right. Easy ways to stay in shape. http://body.aol.com/fitness/winter-exercise?NCID=aolcmp00300000002489 -------------------------------1200271739 Content-Type: text/html; charset="US-ASCII" Content-Transfer-Encoding: quoted-printable
So the solid state does the same thing as the old mechanical relay....m= akes=20 sense....I thought it might have needed an update to the EC2 for the solid s= tate=20 relay. I do have power to my secondary injectors, i just cant hear them clic= k.=20 Whats the proper test to check out the injectors? I checked them with a test= =20 light and have power to one side, then when I check the other side (ground w= ith=20 a test light), I get a click from the connector  to my suprise. must be= =20 those resistors Bob installed??? Just didn't expect any noise from there.
 
I'll send my EC2 to you Tracy for an update. I'm not criticizing about=20 updates, sorry if you took it that way.....when i said i was downloading the= =20 manual instead of working... I should have said....at work. I scour you= r=20 web page daily looking for any 20B updates...once again at work....when I sh= ould=20 be working.
 
I dont have any qualms about paying for an update.....glad your there t= o do=20 it. I'll  remove it tonight and send it tomorrow.
 
Thanks everyone for the info
 
Bob Mears
Supermarine Spitfire




= Start the year off right. Easy ways to stay= in shape in the new year.
-------------------------------1200271739--