----- Original Message -----
Sent: Friday, October 14, 2005 2:32 PM
Subject: [FlyRotary] Re: injector size stop. I
had both injectors wired (as per schematic) to =20
I think you were wise to
split your injectors power like that, I did not do that and in hind sight
wish I had for the reason you cited.
However, I don't see how
adding a circuit breaker would do that. Now, if you are leaving even 1
of the CB ON then the EC2 is receiving power even if the EC2 CB is
pulled. As long as either the primary or secondary injector has power
on the line (either of your injector CB is pushed in) then the EC2 will get
this voltage. Tracy used to have an LED on the program button of
the EC2 and it would light up when the EC2 controller had power - that is
another way I found out about the sneak circuit. If I turned on an
injector toggle the EC2 program button LED would come on even though its
power switch/CB was off.
So do
you get the 6.5volts when both injector CB are pulled?
Ed
When I turn on the
P.injector switch ON, the EM lights up and I get 6.5V Voltage reading and "Low
Voltage" warning on the EM2 display.
Buly
This happens even when the injector power
CB is pulled on the primary injectors??
Ed