Return-Path: <13brv3@bellsouth.net> Received: from imf24aec.mail.bellsouth.net ([205.152.59.72] verified) by logan.com (CommuniGate Pro SMTP 4.1.1) with ESMTP id 2531926 for flyrotary@lancaironline.net; Mon, 18 Aug 2003 09:01:46 -0400 Received: from rad ([68.212.14.21]) by imf24aec.mail.bellsouth.net (InterMail vM.5.01.05.27 201-253-122-126-127-20021220) with ESMTP id <20030818130146.NMHC19510.imf24aec.mail.bellsouth.net@rad> for ; Mon, 18 Aug 2003 09:01:46 -0400 From: "Russell Duffy" <13brv3@bellsouth.net> To: "'Rotary motors in aircraft'" Subject: RE: [FlyRotary] Re: mismatched injectors? Date: Mon, 18 Aug 2003 08:01:47 -0500 Message-ID: <009001c36588$e223cae0$0201a8c0@rad> MIME-Version: 1.0 Content-Type: multipart/alternative; boundary="----=_NextPart_000_0091_01C3655E.F94DC2E0" X-Priority: 3 (Normal) X-MSMail-Priority: Normal X-Mailer: Microsoft Outlook, Build 10.0.4510 Importance: Normal In-Reply-To: X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2800.1165 This is a multi-part message in MIME format. ------=_NextPart_000_0091_01C3655E.F94DC2E0 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: quoted-printable Rusty, Mode 7 is preset in the EC2 to run all injectors above 15" MAP. = You can adjust it lower (I think) TJ<>< =20 The adjustment is to set the throttle for whatever MAP you want the transition to occur at, and hit the set button in mode 7. If I really = want the transition to occur at a MAP below the engine operating range, I'll = have to use a vacuum pump to pull the MAP sensor down to that range, then hit = set in mode 7. That will be easy if the EC-2 will accept a mode 7 setting = with the engine not running. I suppose you can still do this with the engine running, but it will be a bit trickier. I'll ask Tracy about this = today. =20 I agree that this shouldn't be necessary, since Al is using the same injectors with no problems, but I would like to try it for the sake of seeing how it works. =20 =20 Rusty =20 ------=_NextPart_000_0091_01C3655E.F94DC2E0 Content-Type: text/html; charset="us-ascii" Content-Transfer-Encoding: quoted-printable Message
Rusty, Mode 7 is preset in the EC2 to run all = injectors=20 above 15" MAP.  You can adjust it lower (I = think)
TJ<><
 
The adjustment is to set the throttle = for whatever=20 MAP you want the transition to occur at, and hit the set button in mode = 7. =20 If I really want the transition to occur at a MAP below the engine = operating=20 range, I'll have to use a vacuum pump to pull the MAP sensor down to = that range,=20 then hit set in mode 7.  That will be easy if the EC-2 will=20 accept a mode 7 setting with the engine not running.  I = suppose you=20 can still do this with the engine running, but it will be a bit=20 trickier.  I'll ask Tracy about this = today.
 
I agree that this shouldn't be=20 necessary, since Al is using the same injectors with no = problems, but=20 I would like to try it for the sake of seeing how it works. =20
 
Rusty
 
------=_NextPart_000_0091_01C3655E.F94DC2E0--