X-Virus-Scanned: clean according to Sophos on Logan.com Return-Path: Received: from fed1rmmtao05.cox.net ([68.230.241.34] verified) by logan.com (CommuniGate Pro SMTP 4.3c5) with ESMTP id 949865 for flyrotary@lancaironline.net; Thu, 19 May 2005 12:10:44 -0400 Received-SPF: none receiver=logan.com; client-ip=68.230.241.34; envelope-from=ALVentures@cox.net Received: from BigAl ([68.7.14.39]) by fed1rmmtao05.cox.net (InterMail vM.6.01.04.00 201-2131-118-20041027) with ESMTP id <20050519160945.HNDU8651.fed1rmmtao05.cox.net@BigAl> for ; Thu, 19 May 2005 12:09:45 -0400 From: "Al Gietzen" To: "'Rotary motors in aircraft'" Subject: RE: [FlyRotary] EC-2 Breakers Date: Thu, 19 May 2005 09:09:48 -0700 Message-ID: <001e01c55c8d$2e0ac8d0$6400a8c0@BigAl> MIME-Version: 1.0 Content-Type: multipart/alternative; boundary="----=_NextPart_000_001F_01C55C52.81ABF0D0" X-Priority: 3 (Normal) X-MSMail-Priority: Normal X-Mailer: Microsoft Outlook, Build 10.0.6626 Importance: Normal In-Reply-To: X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2900.2180 This is a multi-part message in MIME format. ------=_NextPart_000_001F_01C55C52.81ABF0D0 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit Subject: [FlyRotary] EC-2 Breakers Ed, Since you're running breakers on the flight critical stuff, can you tell me the recommended breaker size for the EC-2 controller? Tracy seems to have hidden this information somewhere in the fine print. I'm assuming that it would be the same for the 3-rotor engine? Mark S. Mark; The EC2 takes very little current. A 5 amp breaker and #22 wire is fine. Al ------=_NextPart_000_001F_01C55C52.81ABF0D0 Content-Type: text/html; charset="us-ascii" Content-Transfer-Encoding: quoted-printable

Subject: [FlyRotary] EC-2 Breakers

 

Ed,

Since you’re running = breakers on the flight critical stuff, can you tell me the recommended breaker = size for the EC-2 controller?  Tracy seems = to have hidden this information somewhere in the fine print.  I’m = assuming that it would be the same for the 3-rotor engine?  =

 

Mark S.

Mark;

 

The EC2 takes very little = current.  A 5 amp breaker and #22 wire is fine.

 

Al

------=_NextPart_000_001F_01C55C52.81ABF0D0--