First of all...thanks to everyone that has tried to help me with my engine surge (fuel related) problem on my normally aspirated Lancair IV. I have throughly checked and tested everything suggested so far. There are no tank vent issues and a vacuum test of the entire system from the engine driven fuel pump back to the tanks proved there is no air getting into the system. I even replaced the o rings on the inlet and outlet sides of the electric fuel pump just to be sure. Unfortunately my test flight this morning confirmed that the issue still remains.
This is what
happened. On a 50 mile cross country where I took off and climbed to 7,500 I experienced zero issues. I landed took on some fuel and took off for home. I climbed to 7,500 again and saw that the fuel flow and fuel pressure gauges were fluctuating. Since this occurrence preferred my engine surge problem in the past I knew it was coming and it did. The engine began surging and continued to do so until I turned on the electric ( back up) fuel pump. The engine and gauge readings stabilized immediately.
So this is where I am...I know I do not have any vacuum (air) leaks from the tanks through to the engine driven pump, nor do I have any restrictions in the fuel lines or fuel tank vents. I have replaced my engine driven pump. All symptoms remain.
Question...if I am at cruise settings and leaned out reading 16GPH on the fuel flow and 10PSI on the fuel pressure should this readings rise when I turn
the electric fuel pump on? My GPH goes from 16 to 21 and my fuel pressure goes from 10 to 15 or higher.
Sent from my iPad