Lorn,
My indication of a low battery the fuel flow stopped indicating while in flight. After landing, the unit would not power up.
I don't know about the EPI-800, but you reset the VM1000 by holding certain buttons and then powering it up. The instructions are in the VM user manual.
Bucky




----- Original Message ----- From: "Lorn H Olsen" <lorn@dynacomm.us>
To: <lml@lancaironline.net>
Sent: Wednesday, May 19, 2010 8:50 AM
Subject: [LML] Re: Vision Microsystems VM 1000 problem


I have an EPI-800. I replaced the battery about 7 years ago.

Does anyone know what the indications are of the battery needing replacement?

On the EPI-800, the tach hours goes to zero with this replacement. I think that that is all that is reset. Vision Micro sent me a piece of equipment that I could reset the tach hours with. I sent it back when I was finished. Does anyone have or know about this piece of equipment?

Lorn

From: "bucky" <bwhittier@ltol.com>
Date: May 18, 2010 3:57:43 PM EDT

It is a battery/clock chip p/n M48T02-200PC1 FROM Digi-Key. It was $15.00 two years ago. It will work on VM1000 OR EPI-800.
Be sure to dicharge static when opening the DPU.
Bucky Whittier

--
Lorn H. 'Feathers' Olsen, MAA, ASMEL, ASES, Comm, Inst
DynaComm, Corp., 248-345-0500, mailto:lorn@dynacomm.us
LNC2, FB90/92, O-320-D1F, 1,700 hrs, N31161, Y47, SE Michigan


--