Mailing List lml@lancaironline.net Message #44341
From: <Sky2high@aol.com>
Sender: <marv@lancaironline.net>
Subject: Re: [LML] Re: Electrical Issue
Date: Mon, 08 Oct 2007 09:46:15 -0400
To: <lml@lancaironline.net>
In a message dated 10/7/2007 9:42:16 P.M. Central Daylight Time, super_chipmunk@roadrunner.com writes:
Voltage sensing is in reference to ground- if the ground varies (stray
voltage) it can also cause problems. In my case I think the shield
provided an alternate ground path that differed from the primary ground
connection.

  Where are the strobes grounded? 
Super,
 
That is a super analysis.  Yes, loose connections and ground loops - time for a visit to the "Which" Doctor.........
 
Grayhawk




See what's new at AOL.com and Make AOL Your Homepage.