Try to reach Mark Davis across
lml…
Regards
Lino
-----Ursprüngliche Nachricht-----
Von: Lino Missaggia (G)
[mailto:lino.missaggia@m-engineering.net]
Gesendet: Dienstag, 21. August
2007 21:38
An: 'Mark Davis'
Betreff: Flap-Box-Failure
Dear Mr. Davis,
Thank you for your Mail, I’ll try an email
again! ;-)
I saw, that you switched the selector from position 3
to 4, expecting to set the device in Auto-Mode
BUT: the position 4 sets the 5.th step (flaps full
up) when using 5 steps in flap-movement!
The correct switch positions for auto-mode are as
follows:
Position
Steps for flap-movement
5
3 steps (0, 1, 2)
6
4 steps (0, 1, 2, 3)
7
5 steps (0, 1, 2, 3, 4)
Hope you will receive this email, because the others
didn’t work!?
I will make a wiring diagram for the resistors to
connect the sensor-outputs and email or fax it to you soon!
You should then review it, perhaps I have
misunderstood something with your voltages…
Lino Missaggia
------------------------------------------------------------
Missaggia Engineering GmbH
Ingenieurbüro für Automation,
Hard & Software-Entwicklung,
Netzwerk & Kommunikationstechnik
Bahnhofstrasse 46
CH-9450 Altstaetten (SG)
Tel: +41 71 750 03 35
Fax: +41 71 750 03 36
Mail: lino.missaggia@m-engineering.net
Web: http://www.m-engineering.net
------------------------------------------------------------