X-Virus-Scanned: clean according to Sophos on Logan.com Return-Path: Sender: To: lml@lancaironline.net Date: Tue, 21 Aug 2007 19:00:16 -0400 Message-ID: X-Original-Return-Path: Received: from mail17.bluewin.ch ([195.186.18.64] verified) by logan.com (CommuniGate Pro SMTP 5.1.11) with ESMTP id 2276811 for lml@lancaironline.net; Tue, 21 Aug 2007 16:30:06 -0400 Received-SPF: none receiver=logan.com; client-ip=195.186.18.64; envelope-from=lino.missaggia@m-engineering.net Received: from PcMee00 (213.3.10.4) by mail17.bluewin.ch (Bluewin 7.3.121) id 46C9BEB900053D21 for lml@lancaironline.net; Tue, 21 Aug 2007 20:29:08 +0000 From: "Lino Missaggia \(G\)" X-Original-To: "'Lancair Mailing List'" Subject: WG: Flap-Box-Failure X-Original-Date: Tue, 21 Aug 2007 22:26:20 +0200 X-Original-Message-ID: <000201c7e431$88d5c570$1963a8c0@PcMee00> MIME-Version: 1.0 Content-Type: multipart/alternative; boundary="----=_NextPart_000_0003_01C7E442.4C610670" X-Priority: 3 (Normal) X-MSMail-Priority: Normal X-Mailer: Microsoft Outlook, Build 10.0.6822 Importance: Normal Thread-Index: AcfkKtkGpoljjBQvRWKQ3dHqd7asSQABodPA X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2800.1896 This is a multi-part message in MIME format. ------=_NextPart_000_0003_01C7E442.4C610670 Content-Type: text/plain; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable Try to reach Mark Davis across lml=85 =20 Regards Lino =20 =20 -----Urspr=FCngliche Nachricht----- Von: Lino Missaggia (G) [mailto:lino.missaggia@m-engineering.net]=20 Gesendet: Dienstag, 21. August 2007 21:38 An: 'Mark Davis' Betreff: Flap-Box-Failure =20 Dear Mr. Davis, =20 Thank you for your Mail, I=92ll try an email again! ;-) =20 I saw, that you switched the selector from position 3 to 4, expecting to = set the device in Auto-Mode BUT: the position 4 sets the 5.th step (flaps full up) when using 5 = steps in flap-movement! The correct switch positions for auto-mode are as follows: Position Steps for flap-movement 5 3 steps (0, 1, 2) 6 4 steps (0, 1, 2, 3) 7 5 steps (0, 1, 2, 3, 4) =20 Hope you will receive this email, because the others didn=92t work!? =20 I will make a wiring diagram for the resistors to connect the = sensor-outputs and email or fax it to you soon! You should then review it, perhaps I have misunderstood something with = your voltages=85 =20 Have a nice time Best regards =20 Lino Missaggia ------------------------------------------------------------ Missaggia Engineering GmbH Ingenieurb=FCro f=FCr Automation, Hard & Software-Entwicklung, Netzwerk & Kommunikationstechnik Bahnhofstrasse 46 CH-9450 Altstaetten (SG) Tel: +41 71 750 03 35 Fax: +41 71 750 03 36 Mail: lino.missaggia@m-engineering.net Web: http://www.m-engineering.net ------------------------------------------------------------ =20 =20 ------=_NextPart_000_0003_01C7E442.4C610670 Content-Type: text/html; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable

Try to reach = Mark Davis across lml…

 

Regards

Lino

 

 

-----Urspr=FCngliche Nachricht-----
Von: Lino Missaggia (G) [mailto:lino.missaggia@m-engineering.net]
Gesendet: Dienstag, 21. = August 2007 21:38
An: 'Mark Davis'
Betreff: = Flap-Box-Failure

 

Dear Mr. Davis,

 

Thank you for your Mail, I’ll try an = email again! ;-)

 

I saw, that you switched the selector from = position 3 to 4, expecting to set the device in Auto-Mode

BUT: the position 4 sets the 5.th step (flaps = full up) when using 5 steps in flap-movement!

The correct switch positions for auto-mode are = as follows:

Position      &nb= sp;     Steps for flap-movement

5        = ;            =             &= nbsp;           3 steps (0, 1, 2)

6        = ;            =             &= nbsp;           4 steps (0, 1, 2, 3)

7        = ;            =             &= nbsp;           5 steps (0, 1, 2, 3, 4)

 

Hope you will receive this email, because the = others didn’t work!?

 

I will make a wiring diagram for the resistors = to connect the sensor-outputs and email or fax it to you = soon!

You should then review it, perhaps I have misunderstood something with your voltages…

 

Have a nice time

Best regards

 

Lino Missaggia
------------------------------------------------------------
Missaggia Engineering GmbH
Ingenieurb=FCro f=FCr Automation,
Hard & Software-Entwicklung,
Netzwerk & Kommunikationstechnik
Bahnhofstrasse 46
CH-9450 Altstaetten (SG)

Tel:     +41 71 750 03 35
Fax:    +41 71 750 03 36
Mail:    
lino.missaggia@m-engineering.net
Web:   
http://www.m-engineering.net
------------------------------------------------------------

 

 