Mailing List lml@lancaironline.net Message #43025
From: Lancair <lancair-esp@ustek.com>
Sender: <marv@lancaironline.net>
Subject: Therm-X deice
Date: Wed, 11 Jul 2007 16:27:43 -0400
To: <lml@lancaironline.net>
 
Columbia has a copper mesh that shorted to the 100a 70vDC power - never a good thing!  The RDD equipment is the same but the installation is different.  My plane has large insulators that preclude this short. 
 
Robert M. Simon
ES-P N301ES


From: Bill Wade [mailto:dhc1@gwi.net]
Sent: Tuesday, July 10, 2007 11:41 AM
To: lml@lancaironline.net
Subject: Therm-X deice

  There was some discussion earlier about deice systems- I'm interested in the Therm-X system myself. I ran across an AD for the Columbia aircraft ( 2006-25-08 ) that mandates rendering the system inoperative effective 12/21/06. This is to prevent a short at the connector that can damage the wings and horizontal stabilizer.
 
  There was no mention of this that I could find on the Kelley website. Even though AD's don't apply to Experimentals, I expect the equipment supplied by RDDent is similar.  -Bill Wade
 
 