Robert writes: << But
the problem brought up a limitation to my panel - lack of ADHRS redundancy. I
started shopping and found that a second Pinpoint might cost $17k whilst a
new-and-improved Crossbow 425 is about $3k. >>
Brent
writes: That is not how the system was designed to be
configured.
Brent,
Perhaps we are speaking of different configurations. I do
not plan to have two dissimilar ADHRS feeding all three Cheltons at the same
time. Rather I had planned to have the Pinpoint feed #1 and #3 and have
the Crossbow feed #2. Since each screen would be set for it's
respective data source there should be no conflict - or so I thought.
(Yes? No?)
Another configuration would be to set all three Cheltons
to read the Pinpoint as prime and the Crossbox as secondary, and have a selector
switch to choose the source. Normally all three would use the Pinpoint,
much as I have now. If the screen were to go blue then I would
throw the switch and feed all three from the Crossbow. Any reason
that this would not work?
Robert M. Simon
ES-P N301ES
(BTW - every e-mail that I
send to the address listed on your communications bounces back. Is brent@regandesigns.com still
valid?)
|