X-Virus-Scanned: clean according to Sophos on Logan.com X-SpamCatcher-Score: 1 [X] Return-Path: Received: from [161.88.255.139] (account marv@lancaironline.net) by logan.com (CommuniGate Pro WEBUSER 5.1.4) with HTTP id 1743882 for lml@lancaironline.net; Mon, 08 Jan 2007 10:23:16 -0500 From: "Marvin Kaye" Subject: Re: [LML] Re: Current fault detector To: lml X-Mailer: CommuniGate Pro WebUser v5.1.4 Date: Mon, 08 Jan 2007 10:23:16 -0500 Message-ID: In-Reply-To: <002b01c73335$dbc40b50$6801a8c0@PhiPounder> References: <002b01c73335$dbc40b50$6801a8c0@PhiPounder> X-Priority: 3 MIME-Version: 1.0 Content-Type: text/plain;charset="iso-8859-1";format="flowed" Content-Transfer-Encoding: 8bit Posted for "Wally Bestgen" : Hamid, The solenoid closes the fuel vent. The theory is: if the current draw is zero the selonild has failed and the vent is open, making it possible under certain filght conditions to allow air into the fuel system. This detector tells the pilot that the solenoid is not producing any resistance and must be assumed to have failed. Same with the pitot and prop heat. Wally