Mailing List lml@lancaironline.net Message #3168
From: Angier M. Ames <alphadog@nii.net>
Subject: Re: 14v Master Relay
Date: Mon, 16 Aug 1999 23:56:18 -0400
To: <lancair.list@olsusa.com>
         <<<<<<<<<<<<<<<<--->>>>>>>>>>>>>>>>
          <<  Lancair Builders' Mail List  >>
          <<<<<<<<<<<<<<<<--->>>>>>>>>>>>>>>>
>>
Thought some of you might like to hear the final word on this subject
from Bob Nuckolls

Angier Ames.

It IS normal for a continuous duty contactor to run too hot to touch.
   You can get both continuous or intermittant duty contactors in that
   package. Use an ohmmeter to measure the coil resistance of your
   unit. If it's over 10 ohms, then it is indeed a continuous duty
   device and uses about 10-15 watts of power to keep it closed . . .
   it WILL run pretty toasty.

       Bob . . .
                       ////
                      (o o)
       ===========o00o=(_)=o00o=========
       <  Independence Kansas: the     >
       <  Jurasic Park of aviation.    >
       <  Your source for brand new    >
       <  40 year old airplanes.       >
       =================================
         http://www.aeroelectric.com

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
LML homepage:   http://www.olsusa.com/Users/Mkaye/maillist.html
Subscribe (FEED) Subscribe (DIGEST) Subscribe (INDEX) Unsubscribe Mail to Listmaster