Steve asks:
<<Can you order in less than 50 yard increments?>>

I do not know what their current policy is or if they sell through distributors.

This may be something Vern may be interested in stocking at Lancair.  As I recall you need about three yards to do the cowling and wheel well. I would recommend that anyone interested in using this material send Vern an email that says:

Dear Vern:

If you decide to stock ZertexPlus 600A I would order (how many you need) yards.

Please post your plans on the Lancair List.

Thank you.
Joe Builder

If Vern gets enough interest then everybody benefits.

Compliments of the season,
Brent Regan

<<I used a product called ZetexPlus 600 A   (A = Aluminum Foil laminated ) manufactured by Newtex Industries 716 924 9135 www.newtex.com.  This is remarkable stuff. After shutdown the areas protected by the Zetex closest to the turbos are cool to the touch while the areas not protected but away from the turbos are 120+ degrees. I also lined the nose wheel well with this stuff to give additional fire protection.  It is thin and light and installs easily with 3M 777 spray adhesive. Seal the perimeter from oil with RTV silicone. I have repaired damage to the aluminum outer layer by gluing down a patch heavy duty kitchen aluminum foil with high temperature RTV silicone.