Hi Charlie,
Latest version of installation guide was changed to all 22ga wire but 24ga is fine for everything except power, injector return and injector driver lines.
Tracy
Sent from my iPad
> On Mar 21, 2014, at 11:00, Charlie England <ceengland7@gmail.com> wrote:
>
> Q for Tracy:
>
> My EC-2 instructions specify 20AWG & 22AWG wire. Any reason to not use 24AWG wire on the low current (signal) lines? I've got a full roll of 24AWG, & with a 5A rating and short runs, it would seem to be fine for signal lines. My bundles will be smaller and I might even save an ounce. :-)
>
> Thanks,
>
> Charlie
>
> --