X-Virus-Scanned: clean according to Sophos on Logan.com Return-Path: Received: from mail-bw0-f226.google.com ([209.85.218.226] verified) by logan.com (CommuniGate Pro SMTP 5.3c3) with ESMTP id 4022406 for flyrotary@lancaironline.net; Tue, 15 Dec 2009 15:49:22 -0500 Received-SPF: pass receiver=logan.com; client-ip=209.85.218.226; envelope-from=msteitle@gmail.com Received: by bwz26 with SMTP id 26so279385bwz.27 for ; Tue, 15 Dec 2009 12:48:46 -0800 (PST) DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=gmail.com; s=gamma; h=domainkey-signature:mime-version:received:in-reply-to:references :date:message-id:subject:from:to:content-type; bh=JXLMJlmAIWGxfGIiiAAxEjeDhdqB0EyGocjGwf4PQMs=; b=Hfor6v3tEgJp82wm9LgyhpYfp2QGY2BGzuNz9ITxOqfsaad4dD5VHTu4EInljP1Xn8 pdAgPtJkwp+m1YvrJO2UWpVnHFE16Gu40udLjkryjcl5+qe0C8r6gYAzhU0Uzz6v9wfy DZAiqb62HyHEGTOrJvZCFHAZnblTWSQCv+Mfw= DomainKey-Signature: a=rsa-sha1; c=nofws; d=gmail.com; s=gamma; h=mime-version:in-reply-to:references:date:message-id:subject:from:to :content-type; b=Oh5+v5sUJX01r3IWV2pM8CgzGVEhmhD9QAUc6hj5GGKvOt0p1C+AdC2zoWYaApDL8T qIjUl+jsKsEeN06SPd/ELdW0IvHQQZ2xuTU33/xT9qlPrw+oLt47xepsQfMwz6BgWxcR /vI6DTpfporxzNffXBWTH/lt4cuyelKYKNGM0= MIME-Version: 1.0 Received: by 10.204.25.66 with SMTP id y2mr32540bkb.59.1260910125876; Tue, 15 Dec 2009 12:48:45 -0800 (PST) In-Reply-To: References: Date: Tue, 15 Dec 2009 14:48:45 -0600 Message-ID: <5cf132c0912151248m6fc59808pc8c456cae8ede03@mail.gmail.com> Subject: Re: [FlyRotary] Re: Oil cooler From: Mark Steitle To: Rotary motors in aircraft Content-Type: multipart/alternative; boundary=00032555f4722587b4047aca8482 --00032555f4722587b4047aca8482 Content-Type: text/plain; charset=windows-1252 Content-Transfer-Encoding: quoted-printable Jeff, Is the black tube on the backside of the oil cooler for cabin heat? How well does that work? Mark On Tue, Dec 15, 2009 at 2:16 PM, Jeff Whaley wrote: > Al, no I do not measure =93before and after=94; it=92s measured at block= output > near standard oil filter pedestal and is feed to PSRU input =85 see attac= hed > (this photo shows the first cooler input, the pressure sender and the > return line from second cooler) =85 if I understand the oil flow correctl= y, > this is after the coolers. > > My max oil pressure was 80 psi when I had one cooler and is still max 80 > psi with 2 coolers =96 typical operating pressure is 75 psi at 5500 rpm. > > Jeff > > > > *From:* Rotary motors in aircraft [mailto:flyrotary@lancaironline.net] *O= n > Behalf Of *Al Gietzen > *Sent:* Tuesday, December 15, 2009 2:05 PM > *To:* Rotary motors in aircraft > *Subject:* [FlyRotary] Re: Oil cooler > > > > Mark, I have two of the DB-30416, single-pass coolers =85 no measureable > pressure drop with 2 in series =85 I=92m seeing 80 psi max with the 13B. > > JWW > > > > What do you mean =93 . =85 no measurable pressure drop=94? Are you measu= ring > pressure before and after the 2 coolers? > > > > Al G > > -- > Homepage: http://www.flyrotary.com/ > Archive and UnSub: > http://mail.lancaironline.net:81/lists/flyrotary/List.html > > --00032555f4722587b4047aca8482 Content-Type: text/html; charset=windows-1252 Content-Transfer-Encoding: quoted-printable
Jeff,
=A0
Is the black tube on the backside of the oil cooler for cabin heat?=A0= How well does that work?=A0
=A0
Mark

On Tue, Dec 15, 2009 at 2:16 PM, Jeff Whaley <jwhaley@datacast= .com> wrote:

Al, = no I do not measure =93before and after=94; it=92s measured at block output= near standard oil filter pedestal and is feed to PSRU input =85 see attach= ed (this photo =A0shows the first =A0cooler input, the pressure sender and = the return line from second cooler) =85 if I understand the oil flow correc= tly, this is after the coolers.

My m= ax oil pressure was 80 psi when I had one cooler and is still max 80 psi wi= th 2 coolers =96 typical operating pressure is 75 psi at 5500 rpm.

Jeff=

=A0<= /span>

From:<= span style=3D"FONT-SIZE: 10pt"> Rotary motors in aircraft [mailto:flyrotary@lancair= online.net] On Behalf Of Al Gietzen
Sent: Tuesday, December 15, 2009 2:05 PM
To: Rotary motors= in aircraft
Subject: [FlyRotary] Re: Oil cooler

=

=A0

Mark, I have two of the DB-30416, single-pass cool= ers =85 no measureable pressure drop with 2 in series =85 I=92m seeing 80 p= si max with the 13B.

JWW

=A0

What do= you mean =93 . =85 no measurable pressure drop=94?=A0 Are you measuring pr= essure before and after the 2 coolers?

=A0

Al G


--