Return-Path: Received: from [65.33.166.167] (account ) by logan.com (CommuniGate Pro WebUser 4.0) with HTTP id 1843636 for ; Wed, 23 Oct 2002 20:41:13 -0400 From: "Marvin Kaye" Subject: Re: [FlyRotary] Re: EWP Tech Data Take 1,000,003 To: flyrotary X-Mailer: CommuniGate Pro Web Mailer v.4.0 Date: Wed, 23 Oct 2002 20:41:13 -0400 Message-ID: In-Reply-To: <000501c27af1$64183410$38273d42@office> MIME-Version: 1.0 Content-Type: text/plain; charset="ISO-8859-1"; format="flowed" Content-Transfer-Encoding: 8bit Posted for "Marc Wiese" : Al Unfortunately the 20B used a cast iron water pump (like the 13B to 1991 but maybe run in reverse, I haven't confirmed that). The 13Brew (93+)has an aluminum pump AND housing. The 13B rew has a water pump that is different than the 13s before it. The pump and the housing it is mounted in is aluminum. The radiator heat dissipation capacity was increased (to 40,000 kcal/h), and the radiator cap opening pressure was increased (to 16-21 psi, but a recall adjusted that again). No figures on flow rates were given. [Marc Wiese]