Mailing List flyrotary@lancaironline.net Message #18327
From: Bob White <bob@bob-white.com>
Subject: Re: [FlyRotary] Re: EWP Test Results/DRAG
Date: Thu, 3 Mar 2005 16:53:55 -0700
To: Rotary motors in aircraft <flyrotary@lancaironline.net>

Hi Tracy,

Here's the data from the Engineering Toolbox.  The viscosity changes a
factor of 4 from 80 to 200 F.  That site has an enormous amount of good
information.

See
http://www.engineeringtoolbox.com/ethylene-glycol-24_146.html
for the whole chart.

Ethylene Glycol Solution (% by volume) 50%
Temp F    Dynamic Viscosity __ (centpoise)
     0           22
   40            6.5
   80            2.8
 120            1.5
 160            0.95
 200            0.7

Bob W.


On Thu, 3 Mar 2005 18:18:43 -0500
"Tracy Crook" <lors01@msn.com> wrote:

> Ernest,
> I had no idea that water viscosity changed that much with temperature.  Is the same true of 50 - 50 glycol & water?
>
> Tracy
>
>
--
http://www.bob-white.com
N93BD - Rotary Powered BD-4 (real soon)
Subscribe (FEED) Subscribe (DIGEST) Subscribe (INDEX) Unsubscribe Mail to Listmaster