Return-Path: Received: from [65.54.169.58] (HELO hotmail.com) by logan.com (CommuniGate Pro SMTP 4.2.5) with ESMTP id 524724 for flyrotary@lancaironline.net; Tue, 09 Nov 2004 13:24:34 -0500 Received-SPF: pass receiver=logan.com; client-ip=65.54.169.58; envelope-from=lors01@msn.com Received: from mail pickup service by hotmail.com with Microsoft SMTPSVC; Tue, 9 Nov 2004 10:24:03 -0800 Received: from 65.54.98.148 by BAY3-DAV28.phx.gbl with DAV; Tue, 09 Nov 2004 18:23:13 +0000 X-Originating-IP: [65.54.98.148] X-Originating-Email: [lors01@msn.com] X-Sender: lors01@msn.com From: "Tracy Crook" To: "Rotary motors in aircraft" References: Subject: Re: [FlyRotary] Re: EGT sensors Date: Tue, 9 Nov 2004 13:23:13 -0500 MIME-Version: 1.0 Content-Type: multipart/alternative; boundary="----=_NextPart_000_007E_01C4C65F.43CFC860" X-Priority: 3 X-MSMail-Priority: Normal X-Mailer: MSN 9 X-MimeOLE: Produced By MSN MimeOLE V9.10.0009.2900 Seal-Send-Time: Tue, 9 Nov 2004 13:23:13 -0500 Message-ID: X-OriginalArrivalTime: 09 Nov 2004 18:24:03.0878 (UTC) FILETIME=[4AAB5C60:01C4C689] This is a multi-part message in MIME format. ------=_NextPart_000_007E_01C4C65F.43CFC860 Content-Type: text/plain; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable The EM2 manual explains how to make your own thermocouples from = thermocouple wire. The EGT sensor I have came with a Westach instrument, but = basically it's just a thermocouple wire hooked to a bolt (probe) which is held = in the exhaust stream by a clamp around the exhaust pipe with a hole for the = bolt. I'm not sure where you could put a second sensor in a turbo = installation unless you drilled the cast manifold. I added a second sensor on the = turbo heat shield. John I should have put in an exception for EGT sensors which require hi = temp insulation and inconel sleeves into the pipe. Don't try this at = home. All other applications - home brew away. Tracy (color for Rusty) ------=_NextPart_000_007E_01C4C65F.43CFC860 Content-Type: text/html; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable
 
The EM2 manual explains how to make your own thermocouples from=20 thermocouple
wire. The EGT sensor I have came with a Westach = instrument,=20 but basically
it's just a thermocouple wire hooked to a bolt = (probe) which=20 is held in the
exhaust stream by a clamp around the exhaust pipe = with a=20 hole for the bolt.
I'm not sure where you could put a second sensor = in a=20 turbo installation
unless you drilled the cast manifold. I added a = second=20 sensor on the turbo
heat shield.

John

I should have put in an = exception for=20 EGT sensors which require hi temp insulation and inconel sleeves into = the=20 pipe.  Don't try this at home.  All other applications - = home brew=20 away.
 
Tracy  (color for Rusty)
 