X-Virus-Scanned: clean according to Sophos on Logan.com Return-Path: Sender: To: lml@lancaironline.net Date: Tue, 18 Jan 2011 21:13:26 -0500 Message-ID: X-Original-Return-Path: Received: from nm17.bullet.mail.ac4.yahoo.com ([98.139.52.214] verified) by logan.com (CommuniGate Pro SMTP 5.4c1) with SMTP id 4790297 for lml@lancaironline.net; Tue, 18 Jan 2011 14:07:54 -0500 Received-SPF: none receiver=logan.com; client-ip=98.139.52.214; envelope-from=mattinlosangeles@yahoo.com Received: from [98.139.52.190] by nm17.bullet.mail.ac4.yahoo.com with NNFMP; 18 Jan 2011 19:07:18 -0000 Received: from [98.139.52.156] by tm3.bullet.mail.ac4.yahoo.com with NNFMP; 18 Jan 2011 19:07:18 -0000 Received: from [127.0.0.1] by omp1039.mail.ac4.yahoo.com with NNFMP; 18 Jan 2011 19:07:18 -0000 X-Yahoo-Newman-Property: ymail-3 X-Yahoo-Newman-Id: 505866.15527.bm@omp1039.mail.ac4.yahoo.com Received: (qmail 70625 invoked by uid 60001); 18 Jan 2011 19:07:18 -0000 DomainKey-Signature:a=rsa-sha1; q=dns; c=nofws; s=s1024; d=yahoo.com; h=Message-ID:X-YMail-OSG:Received:X-Mailer:References:Date:From:Subject:To:In-Reply-To:MIME-Version:Content-Type; b=jZngvXnANmLZBDH02kidHUz5n0BOLCItQr2GSxYo7cMPzTGz9FOiNwq6/BBIYZSPDMZyWhFciRlG12kbNDxKc0u3hqVoiRIVtMgdHYCCk8IC151OmnVxneLxBcovJI6p1jN5VBNh7tpj/afCiwVxUFnri/xb3Ij9pJsJ8XNqQGg=; X-Original-Message-ID: <263282.70537.qm@web161406.mail.bf1.yahoo.com> X-YMail-OSG: sOKZ2UoVM1mpo2mvDzk8UMBdhGqaiNEudGK2f37_tOBdfQm Yyl83HHSO8GqEcBuDkfU0NaIEXJqDru1teX4rcslkvSUC.JBiw5tDtJdpPhB 7TbM8RI9pcevTYtxDjhk2hRHfqSPnZ1okfwnL3l4u6pw7IkD.gkKeKMM4E03 3JbqzXCe_PO_odL38P.QbsingGq9lPic66eE1Fb.68.wjIu7WG5u8CSX7IRf DYdCXD76JEmYt2GwZOiRUeeW8SEo3YkLoPSetAdvdK6du3fFUhRoOv2V1E20 FIgXxKHg- Received: from [63.110.89.212] by web161406.mail.bf1.yahoo.com via HTTP; Tue, 18 Jan 2011 11:07:18 PST X-Mailer: YahooMailRC/555 YahooMailWebService/0.8.107.285259 References: X-Original-Date: Tue, 18 Jan 2011 11:07:18 -0800 (PST) From: Matt losangeles Subject: what is the correct tubing for Oxygen? X-Original-To: Lancair Mailing List In-Reply-To: MIME-Version: 1.0 Content-Type: multipart/alternative; boundary="0-411613295-1295377638=:70537" --0-411613295-1295377638=:70537 Content-Type: text/plain; charset=us-ascii Hello all, I am needing to run some hard line tubing for an oxygen system and I am wondering what type is correct. I looked in the FAA publication and it calls for some sort of copper tubing. I would suspect that aluminum tubing would work just as well if not better plus I likely already have it. I am wondering what is the correct type and what inside diameter someone would suggest to connect directly to the oxygen tank itself. The tank has a maximum pressure of 2014lbs. Would the 5052 stuff that is used on the Legacy landing gear system good enough or is something stronger required? What about 6061. I see that is another type that is easy to get my hands on. Thanks for any info. Matt --0-411613295-1295377638=:70537 Content-Type: text/html; charset=us-ascii
Hello all,
 
I am needing to run some hard line tubing for an oxygen system and I am wondering what type is correct. I looked in the FAA publication and it calls for some sort of copper tubing. I would suspect that aluminum tubing would work just as well if not better plus I likely already have it. I am wondering what is the correct type and what inside diameter someone would suggest to connect directly to the oxygen tank itself. The tank has a maximum pressure of 2014lbs. Would the 5052 stuff that is used on the Legacy landing gear system good enough or is something stronger required? What about 6061. I see that is another type that is easy to get my hands on.
 
Thanks for any info.
 
Matt


--0-411613295-1295377638=:70537--