Jay,
I experienced the same problem when I had adjusted the outer
door attached to the landing gear too tight.
What was happening was the gear would retract and activate the sequence
valve, but the outer door would add some pull down force on the gear because it
was adjusted too tight. As the hydraulic
pressure dropped due to the opening of the sequence valve, the outer door would
pull the strut down just a bit, thus closing the sequence valve. Once the sequence valve was closed hydraulic
pressure was shut off to the inner gear door stopping its motion and the gear
strut would retract. As the gear pulled
up tight the sequence valve would open, starting the cycle all over again.
The symptom is that the inner gear door closes with a jerky
motion. By lengthening the outer gear
door links just a bit, the problem went away.
Jim Thomas
Legacy with 300 hours
|