Mailing List lml@lancaironline.net Message #38676
From: Walter Atkinson <walter@advancedpilot.com>
Sender: <marv@lancaironline.net>
Subject: Re: [LML] Re: TSIO550E Lean of Peak (LOP) Operations
Date: Sat, 25 Nov 2006 23:07:22 -0500
To: <lml@lancaironline.net>
The CHT's at those two different FFs will be dependent on the mass airflow at those two FFs.

Walter


On Nov 24, 2006, at 2:24 PM, Marvin Kaye wrote:



Posted for "Tomas Holbrook" <tomas@tomasdds.com>:

 Jeff:
  My 40.7 hour TSIO-550 E has the same data.  What I find interesting is that
the CHTs at 20 GPH LOP are 310 to 337 and at 18 GPH LOP the are 244-274 at
9500 feet msl.
  Tomas
 N993DT

--
For archives and unsub http://mail.lancaironline.net/lists/lml/

Subscribe (FEED) Subscribe (DIGEST) Subscribe (INDEX) Unsubscribe Mail to Listmaster