From: Jeff Whaley jwhaley@datacast.com <flyrotary@lancaironline.net>
Subject: RE: Alternator Damaged - Internal Short
Date: Thu, 2 Aug 2018 15:39:07 +0000
To: Jeff Whaley <jwhaley@datacast.com>, Rotary motors in aircraft <flyrotary@lancaironline.net>
Bobby, no I did not fuse the B lead.  What amperage would it be if installed?
Jeff

Jeff,

Do you have a fuse in the B lead?

Bobby

-----Original Message-----
From: Jeff Whaley
Sent: August-02-18 10:41 AM
To: Rotary motors in aircraft
Subject: Alternator Damaged - Internal Short

Last Thursday I decided to try my cooling on a hot day 32C (90F); orbiting the airport, the cooling wasn't too bad but while waiting for the temps to stabilize I smelled smoke so landed immediately.  Saw a bit of smoke exiting the oil cooler plenum so thought I was baking some fiberglass.
On the weekend I did a more thorough inspection and found the battery mains cable burned where attached to my alternator cut-out relay and the relay fried to the point that the input terminal was loose.  The connections stayed in place but open-circuited the relay - so the engine never skipped a beat and I was unaware there was an electrical problem at the time. Only reporting this now as it took me a while to get the alternator tested.
Jeff