Bill

The lug connection between my probes and wire are staggered and individually covered with a thick wall heat shrink.  


Bobby

Sent from my iPad

On Jun 22, 2012, at 2:55 PM, "Bill Bradburry" <bbradburry@bellsouth.net> wrote:

> Tracy and others,
>
> I had a problem with the #2 EGT going erratically up to over 2K.  I couldn't
> find anything wrong with the probe, so I sent the EM-2 to Tracy for
> evaluation.  He didn't find anything wrong with the EM-2 so back to the
> drawing board!
>
> I got my hangar mate to come out and give me an assist.  We discovered that
> if I moved the probe back and forth along the exhaust manifold, the output
> of the probe would change up to into the 40s milivolt.  At first I thought
> that I was somehow getting voltage onto the exhaust manifold and it was
> being picked up by the probe.
>
> Turns out that the probe connects to the thermocouple wire with two ring
> connectors and the edges of the ring connectors were cutting thru the
> insulation of the adjacent wire causing a short.
>
> Tracy has sent the EM-2 back and now I need to figure a way to connect the
> wires without causing a short and so that it doesn't cause an error in the
> output.
>
> Anyone have a suggestion about how to do that??
>
> Bill B
>
>
> --