X-Virus-Scanned: clean according to Sophos on Logan.com Return-Path: Received: from mail-pz0-f202.google.com ([209.85.222.202] verified) by logan.com (CommuniGate Pro SMTP 5.3.0) with ESMTP id 4068321 for flyrotary@lancaironline.net; Thu, 07 Jan 2010 14:29:50 -0500 Received-SPF: pass receiver=logan.com; client-ip=209.85.222.202; envelope-from=wdleonard@gmail.com Received: by pzk40 with SMTP id 40so11116163pzk.7 for ; Thu, 07 Jan 2010 11:29:13 -0800 (PST) DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=gmail.com; s=gamma; h=domainkey-signature:mime-version:received:in-reply-to:references :date:message-id:subject:from:to:content-type; bh=R9WflaLemzYCJg4C0ZqYnvFEluRU+zf1H+AeFuRw7uc=; b=WHdzjlinxvtAHRWp+CrPzMG2EExjXhkrxpIaQJO9q1vFJ7NUGZXB6htJC6ZIgvi8fD g1XQ7tRWXw59Km6AHjPj17E5kIJrGxi1D03HoykI1q+Yycpb9e1htxdSZfqQTaeFokVl CuH3lK76wPuh+rSWQSFgYqIrtR+ppYWpRnjNs= DomainKey-Signature: a=rsa-sha1; c=nofws; d=gmail.com; s=gamma; h=mime-version:in-reply-to:references:date:message-id:subject:from:to :content-type; b=PWvQSRtg6GjWy/f6PViCS4QhA9K1pNWt0zsmACa/Q/c1yLCr31dtu8WnXOqjzXgQKz ewiFP7n/C6UZnV90HyQICUCQnj6F5T/a33rZhrGVArJYQ8A/BM04NcrLnynb+rwk81m7 kdPy6/vsiwdu9QAv1ReK+fxq/xRnluVLv6sVQ= MIME-Version: 1.0 Received: by 10.143.153.41 with SMTP id f41mr14927778wfo.331.1262892553914; Thu, 07 Jan 2010 11:29:13 -0800 (PST) In-Reply-To: References: Date: Thu, 7 Jan 2010 11:29:13 -0800 Message-ID: <1c23473f1001071129o1fa33268i880968c9f385a9d7@mail.gmail.com> Subject: Re: [FlyRotary] Re: High voltage problem fixed for real From: David Leonard To: Rotary motors in aircraft Content-Type: multipart/alternative; boundary=001636e0a6fb10c843047c9816af --001636e0a6fb10c843047c9816af Content-Type: text/plain; charset=windows-1252 Content-Transfer-Encoding: quoted-printable So to verify (for me and others who have done the internal disconnect > from output to voltage regulator/field supply); you connected from the > alternator output (=91B=92 terminal) back to the field via a relay; where= the > relay power has the over-voltage protection and panel switch. > Exactly! --=20 David Leonard Turbo Rotary RV-6 N4VY http://N4VY.RotaryRoster.net http://RotaryRoster.net --001636e0a6fb10c843047c9816af Content-Type: text/html; charset=windows-1252 Content-Transfer-Encoding: quoted-printable

So to verif= y (for me and others who have done the internal disconnect from output to v= oltage regulator/field supply); you connected from the alternator output (= =91B=92 terminal) back to the field via a relay; where the relay power has = the over-voltage protection and panel switch.

=A0
Exactly!
--
David Leonard

Turbo Rotary RV= -6 N4VY
http://N4VY.RotaryRoste= r.net
http://RotaryRoster.net
--001636e0a6fb10c843047c9816af--